Current Inventory
Industries Served / Case Studies
Company Profile
Contact Us
Home
Directions to Kono Kogs
Links
|
Process: Can Coating
Problem: Established Company Looking for Economical Replacement Oxidizer with lower maintenance
Equipment: Catalytic Recuperative Oxidizer
18,000 scfm capacity (1995 vintage)
Installed: 2004
Location: MN
 Before
After
Project Details:
Coil coater was previously treating 6,000 scfm of air from a coil coating oven.
With process upgrades they were able to significantly increase process line speed,
which required additional exhaust from the curing ovens. In addition to the need
for more oxidizer capacity, this can coating operation wanted to reduce the solvent
build up in the oxidizer inlet ductwork and fans. The solvents used in this process
have high boiling points. Cleaning of the process exhaust ductwork and fans prior
to the oxidizer was very labor intensive and costly. Can coater wanted to
eliminate the solvent cleanup with the new oxidizer.
Solution Provided by Kono Kogs, Inc.
We worked with our client and their consultant to develop a solution that meets their
capacity requirement, reduces solvent build-up and provides an economical, long life
system for their continued growth.
The oxidizer provided was a well built, late model, catalytic recuperative system that
had been idle for 3 years. We assisted the consultant in designing a recirculation loop
into our oxidizer to address the solvent build up issue they had with the previous oxidizer.
The recirculation loop brings clean, hot air from the catalyst exhaust back into the process
ductwork, upstream of the oxidizer inlet. This hot air maintained the duct temperature above
the condensing point of the solvents, eliminating solvent build up from the point of recirculation
tie-in, through the oxidizer.
The catalytic oxidizer provided by Kono Kogs was priced at less than half of the cost of a new
system. It achieved greater than 98.6% VOC destruction, and eliminated the solvent build up
problem.
Equipment / Services Provided by Kono Kogs, Inc.:
- Refurbished Catalytic Recuperative oxidizer
- Low Capital Cost: Approximately 45% of the cost for a new system
- Energy efficient (70% HX) low temp (650F) operation
- Oxidizer and coating lines optimized to reduce airflow to oxidizer at all times
- Excellent quality, late model (9 year old) system w/20+ year life expectancy
|