Case Studies / Testimonials
Spray Coating of Aluminum Parts
| Problem: |
POTENTIAL to Emit Exceeded VOC Limits for Facility |
| Equipment: |
Regenerative thermal oxidizer (RTO)
9,000 scfm capacity (1996 vintage)
Installed: Fall 2002
Location: Ohio |

Before: 9,000 scfm RTO that was idle for
3 years. Prior to removal and refurb by Kono Kogs. |
|

After: 9,000 scfm RTO refurbished and
installed on a paint spray line. |
Project Details:
Many manufacturers are faced with the POTENTIAL TO EMIT issue. Although
your actual emissions will not be anywhere near the maximum potential
emissions, this is the standard enforced. This client had determined
their emissions were just over the threshold which requires some
form of emission reduction. The client correctly determined that
an RTO was the best technology for their light emission application.
The problem was the capital costs.
Their expected flow rate from two paint spray booths and a curing
oven was 6,000 scfm. Emissions were a light 4 lb/hr maximum, and
an average of 1.5 lb/hr. The process emissions would consist of
n-butanol, i-propanal, and methanol. All these components are easily
treated by most oxidizer technologies. The advantage of one technology
over the other would be determined by the lowest total cost to acquire
and operate. One other concern was the possibility of pass through
of paint solids into the oxidizer. High levels of inorganic particulates
entering an oxidizer can result in plugging. They had already settled
on a regenerative thermal oxidizer, but were expecting to replace
ceramic media annually.
Solution Provided by Kono Kogs, Inc.
Kono Kogs proposed a refurbished, very well built, regenerative
thermal oxidizer (RTO) system with expansion capability of an additional
50%. This system provided excess capacity, which may not be needed
at this facility, but would actually save electric costs compared
to a properly sized RTO, and would achieve greater than 95% thermal
effectiveness at these reduced flows. The unused fan capacity would
also be available as a cushion to overcome resistance created by
potential particulate build-up.
Equipment / Services Provided by Kono Kogs, Inc.:
- Refurbished and warranted, used Regenerative thermal oxidizer
(RTO)
- Low cost RTO at approximately half the cost of quotations for
new RTO’s.
- Oxidizer PLC logic modified to interface with Process & LEL
System
- Partnered with OEM to update PLC, operating program, and provide
support for customer’s hazard analysis.
- The result: a system with operating costs even lower than a
properly sized new system..... at an equipment price of less than
half the cost of new.
|