This used CECO Adwest Retox 10,000 regenerative thermal oxidizer (RTO) has 10,000 scfm capacity. This used RTO is in very good condition; treated emissions from heatset web offset printing press and was taken off-line in November 2022 and is available immediately. It includes a two-chamber design, with random packed ceramic media and a dual poppet (switching) valve configuration plus a VOC entrapment feature.

CECO Adwest Retox RTO systems are designed to provide one of the lowest utility costs (fuel & electric) of any leading oxidizer system. It is a simple RTO with over-sized beds to reduce pressure drop.

This regenerative thermal oxidizer has the following features:

  • Maximum design flow – 10,000 scfm @ up to 300F process emissions
  • Dual bed 95% heat exchanger design (ceramic media included)
  • Pneumatic poppet valve for flow direction changes through media
  • VOC Entrapment (Puff capture) to provide high VOC destruction & eliminate visible emissions
  • Main RTO fan with  TEFC motor and ABB variable frequency drive
  • Maxon Kinemax 4 burner for heat-up
  • Allen Bradley CompactLogix PLC with Beijer operator interface
  • Yokogawa Digital Chart Recorder
  • Combustion blower with TEFC motor
  • Isolation damper with electro-pneumatic actuator
  • Inlet start-up/Fresh air damper with electro-pneumatic actuator
  • Exhaust stack w/test ports (approx 30’ from grade)
  • Fuel gas injection for high fuel efficiency and low NOx operation
  • Complete owner’s manual with electrical and mechanical drawings

See Before & After Photos of Refurbished RTO units by Kono Kogs, or contact our team to speak with an expert.

Specifications
(approximate; Not for Design Purposes):

Weight

Approx. 45,000 lbs (including ceramic media)

Footprint

Approx.  45’ – 5" long, 17' wide

Electrical Requirements

460/3/60, 130 amps

Gas requirements

2,890 scfh max @ 5 psig

Compressed Air requirements

720 cfh @ 90 psi and -40F dew point

* Values displayed are approximate, do not use for design.