Regenerative Thermal Oxidizer Maintenance

Refurbished Regenerative Thermal Oxidizers (RTOs) Inventory

RTO Maintenance, Repairs & Upgrades

Kono Kogs services all types of emission abatement systems and all OEM models. See the helpful resources below detailing common Maintenance, Repairs, and Upgrades.

No items found.

RTO Maintenance, Repairs and Upgrades

Regenerative thermal oxidizers operate under demanding conditions. High temperatures, corrosive compounds, particulate loading and continuous valve cycling can gradually affect performance, even when the system is still running and nothing looks obviously wrong.

Kono Kogs provides regenerative thermal oxidizer maintenance, troubleshooting, repairs and upgrades for all major RTO types and OEM models. We’ve rebuilt or fully refurbished nearly every type of RTO system and can support your equipment on-site or remotely. Sometimes the problem is one failed component, and sometimes the problem is the first sign of a larger issue. We look at the complete system to understand what’s happening and what the situation calls for.

Whether you’re investigating a performance problem, planning a repair or determining whether an older system should be upgraded or rebuilt, our goal is to help you:

  • Reduce unplanned downtime
  • Maintain VOC destruction and thermal efficiency
  • Control fuel and operating costs
  • Extend the service life of existing equipment
  • Keep the system operating within required compliance parameters

For ongoing inspections and scheduled service, our custom KONOCare preventative maintenance plans help identify problems early and maximize oxidizer uptime.

RTO Maintenance Services

Kono Kogs provides maintenance and technical support throughout the life of an RTO, including:

If the need is urgent, our service team is on call 24 hours a day for emergency RTO troubleshooting and repair.

Explore our case studies for examples of RTO repairs, upgrades and rebuilds completed for facilities across a range of industries.

Common Signs an RTO Needs Maintenance

Changes in system performance often provide warning before a major component fails. Contact an experienced RTO technician when you notice:

  • Increasing fuel consumption
  • Reduced airflow capacity
  • Rising pressure drop across the ceramic media beds
  • Increased amperage at the system fan or variable frequency drive
  • Uneven chamber temperatures
  • Difficulty maintaining combustion chamber temperature
  • Frequent alarms or unexplained shutdowns
  • Pressure pulses affecting connected process equipment
  • Valve timing or sealing problems
  • Visible smoke, unusual odors or changes in stack emissions
  • Paint discoloration or hot spots on the exterior shell
  • Air leakage around doors, flanges or duct connections
  • Declining VOC destruction efficiency
  • Process performance problems that may be related to exhaust airflow

These symptoms don’t always point to a single failed component. For example, reduced airflow could result from plugged media, a valve problem, fan performance, duct restrictions or a change in the process airstream. A system-level evaluation is typically the best way to identify the root cause.

RTO Maintenance Checklist

Maintenance needs vary by RTO design, process conditions, operating schedule and equipment history. This checklist covers the primary areas to evaluate when troubleshooting or servicing an RTO, but it should be used along with OEM instructions and a site-specific inspection plan.

Ceramic heat exchange media

  • Check pressure drop across each media bed
  • Review temperature profiles and heat recovery performance
  • Inspect for particulate plugging, fouling or chemical deposits
  • Look for cracked, crushed, shifted or collapsed media
  • Inspect gaps between structured media blocks
  • Evaluate the cold-face support system
  • Determine whether the media can be cleaned or needs to be replaced

Switching valves and valve drives

  • Confirm that valves cycle fully and at the correct timing
  • Inspect valve seats, seals and cushions
  • Check pneumatic cylinders, solenoids, actuators, rack-and-pinion drives and linkages
  • Look for excessive wear, misalignment or air leakage
  • Verify that the valve system is maintaining proper chamber isolation
  • Evaluate recurring compressed-air or winter freeze-up problems

Burner and combustion system

  • Inspect burner condition and flame pattern
  • Verify fuel pressure and combustion air settings
  • Check ignitors, flame scanners and safety interlocks
  • Confirm that the burner is not directing flame toward the ceramic media
  • Review chamber temperatures and burner firing trends
  • Inspect refractory or insulation near the burner

Fans, motors and airflow

  • Check fan rotation, vibration and operating amperage
  • Inspect bearings, belts, couplings and motor condition
  • Review variable frequency drive operation
  • Verify airflow and static pressure
  • Inspect dampers and related ductwork
  • Look for particulate buildup, corrosion or air leakage

Controls and instrumentation

  • Review the alarm and shutdown history
  • Check PLC and HMI operation
  • Verify thermocouple and pressure transmitter readings
  • Test temperature, pressure and airflow sensors
  • Confirm valve timing and process interlocks
  • Inspect electrical connections, wiring and control panels
  • Identify obsolete controls or components before they cause unplanned downtime or limit repair options

Insulation and structural condition

  • Inspect the exterior shell for hot spots or discoloration
  • Check access doors, flanges and penetrations for air leakage
  • Inspect internal ceramic fiber insulation
  • Look for damaged modules, open seams or exposed steel
  • Evaluate the cold-face support and internal structural steel
  • Inspect platforms, ladders and exterior supports where applicable

System performance

  • Compare current operation with original design conditions
  • Review fuel usage, airflow and pressure-drop trends
  • Confirm VOC destruction and thermal efficiency
  • Evaluate process changes that may have altered the exhaust stream
  • Check whether the system is operating within permit and compliance requirements
  • Document recommended repairs, upgrades and replacement priorities

RTO Ceramic Media Maintenance and Replacement

The ceramic media beds within a regenerative thermal oxidizer are critical to its thermal efficiency. They capture heat from the cleaned exhaust stream and transfer it to the incoming process air, reducing the amount of supplemental fuel needed to reach oxidation temperature.

When media performance begins to deteriorate, the cause should be identified quickly to protect against unplanned downtime and maintain high thermal efficiency and VOC destruction efficiency.

Kono Kogs technicians can evaluate the current condition of the heat exchange beds, determine whether cleaning or repair is practical and estimate when media replacement should be considered. RTO ceramic media beds can last up to 20 years in optimal operating conditions, but many factors can contribute to reduced performance.

RTO ceramic media maintenance services include replacement
Ceramic Structure Packing in RTO Combustion Chamber

Particulate plugging

Ceramic heat exchangers allow VOC/HAP-laden air to pass through them as part of the pre-heating (and cooling) process. In airstreams with emissions containing elevated levels of inorganic and organic particulate matter – dust, silicones, various “sticky” VOCs – the ceramic media is susceptible to plugging which will result in poor overall RTO performance and loss of efficiency. 

Signs of plugged ceramic media include:

  • Reduced airflow capacity
  • Increased fuel consumption
  • Increased amperage usage in fan variable speed drives
  • Pressure pulses back to your process
  • Increasing pressure drop
  • Uneven temperature profiles
  • Process performance issues

Depending on the type and severity of the buildup, media cleaning may restore performance. Severely damaged, collapsed or permanently fouled media may require partial or complete replacement.

RTO plugged ceramic media in need of maintenance
Plugged Ceramic Media in an RTO

Ceramic media damage

Besides plugging, media can also be damaged by:

  • Excessive temperature
  • Direct flame impingement
  • Thermal shock
  • Chemical attack
  • Improper installation
  • Failure of the cold-face support
  • Movement or settling within the bed
  • Repeated pressure pulses

The visible condition of the top layer doesn’t always reveal what’s happening deeper in the bed. Pressure-drop testing, temperature analysis and internal inspection may all be needed to determine the full extent of the problem.

Ceramic media bed redesign

To extend ceramic media life where plugging is a recurring issue, our RTO specialists may suggest a redesign of the media bed itself. The best solution may be either a different ceramic media type, or possibly mixtures of multiple types of ceramic media. Occasionally, a feature that “bakes out” sticky organic VOCs may provide extended bed life with no ceramic media changeout required.

RTO Valve Maintenance, Repairs and Upgrades

The switching valve system directs airflow between an RTO’s chambers. Because it cycles continuously during operation, the valve system can be put under stresses that will cause wear and tear over time. The switching valve is one of the few moving parts on an RTO, making maintenance critically important for reliable RTO operation. 

In most cases, inspection and scheduled replacement of key components like valve cushions, solenoid actuators, rack & pinions, etc. may be all that’s needed to prevent most performance issues. Worn components in the valve system can lead to leakage, poor airflow control, and reduced destruction efficiency. Valve problems may also create pressure fluctuations that affect upstream process equipment.

Kono Kogs provides:

  • Valve inspection and troubleshooting
  • Seal, cushion and actuator replacement
  • Pneumatic valve drive repair
  • Electric valve drive retrofits
  • Rotary valve repair and replacement
  • Poppet valve repair and replacement
  • Rotary-to-poppet or poppet-to-rotary evaluations
  • Valve timing and control adjustments

If your plant has a rotary valve RTO, retrofitting an electric RTO valve system might be an option to combat winter freeze-up due to compressed air dew point issues. Electric valve drives also eliminate the common maintenance issues with pneumatically driven valves. Some applications are better suited for poppet valves than rotary valves, so retrofitting poppet valves may be the best solution in some cases. Kono Kogs specializes in these sorts of repairs and upgrades, keeping our clients running with minimal downtime and optimal efficiency. 

Burner and Combustion System Maintenance

The burner system must consistently bring the combustion chamber to the temperature required for VOC destruction without overheating the RTO or damaging internal components.

Burner maintenance and troubleshooting may involve:

  • Inspecting the burner and combustion air system
  • Checking fuel pressure and valve operation
  • Adjusting the air-to-fuel ratio
  • Inspecting the ignitor and flame scanner
  • Testing purge and flame-safety sequences
  • Reviewing burner firing rate and temperature trends
  • Correcting unstable or improperly positioned flame
  • Evaluating combustion chamber temperature control

A burner that’s out of adjustment can increase fuel use, create temperature instability or expose nearby media and insulation to excessive heat. Burners and combustion chambers should be evaluated along with the RTO controls, sensors and airflow conditions.

Fan, Motor and Airflow Maintenance

The exhaust fan must move the required volume of process air through the ductwork, RTO chambers and ceramic media beds. A restriction or mechanical problem anywhere in that path can reduce process capture and affect system performance.

Fan and airflow maintenance may include:

  • Fan vibration and balance checks
  • Bearing, belt and coupling inspection
  • Motor and VFD troubleshooting
  • Amperage and operating-point review
  • Damper inspection and adjustment
  • Airflow and static-pressure testing
  • Ductwork inspection
  • Investigation of unexplained pressure changes

Higher fan amperage doesn’t necessarily mean the fan itself is failing. It can also indicate rising resistance caused by plugged media, a damper problem or a restriction somewhere else in the system.

PLC, HMI and Control System Upgrades

A regenerative thermal oxidizer’s PLC (programmable logic controller) is the brain of its operation, initiating and monitoring system performance through a set of programmed operating instructions. 

Since RTO systems have lengthy lifespans that often outlive their own original PLC technologies, controllers and their associated components often become obsolete well before the rest of the system. Updating PLC components in a regenerative thermal oxidizer can extend its operative life and create new system efficiencies not previously possible. 

Aging PLCs, touchscreens, drives and input/output components can become difficult to support or replace, increasing the risk that a minor electrical failure will cause extended downtime.

Proactively maintaining an RTO’s PLC and associated controls can:

  • Replace obsolete components
  • Improve system diagnostics
  • Provide clearer alarm information
  • Improve temperature or valve control
  • Support new sensors and instrumentation
  • Enable remote troubleshooting
  • Simplify future service and parts replacement
  • Extend the useful life of the existing RTO

Kono Kogs provides PLC and HMI upgrades, control-panel modifications, programming, startup support and configuration for existing oxidizer systems.

Allen-Bradley programmable logic controller with support and upgrades available

Remote RTO Monitoring and Support

With remote monitoring set up on your RTO, you can have our team of experts log on from anywhere to help you troubleshoot a minor problem. Our team can also troubleshoot a major issue quickly to get the RTO running again. Alarms can be set up to notify your team (and ours) when the RTO operates outside of determined parameters. 

With KONOConnect advanced IIoT technology, Kono Kogs technicians can review operating conditions, alarm history, temperature trends and control logic without waiting for an on-site visit. This allows many problems to be identified more quickly and helps determine whether field service or replacement parts are needed.

Remote RTO support can:

  • Reduce travel delays
  • Shorten troubleshooting time
  • Improve communication between plant personnel and technicians
  • Help diagnose intermittent faults
  • Provide access to operating trends and alarm history
  • Reduce unnecessary service visits
  • Support faster recovery after a shutdown

Remote access doesn’t replace physical inspection when mechanical damage, insulation failure or internal fouling is suspected. But it does provide valuable information before our technicians arrive on-site.

Hot Spot and Insulation Repair

RTOs operate with internal temperatures of 1500°F or more in the combustion chamber area and into the ceramic media beds. Protecting the mild steel external shell is critical and is typically accomplished with ceramic fiber insulation modules welded to the internal walls. But small gaps, damaged modules or failed attachment points can expose the shell to excessive heat. 

Warning signs include:

  • Paint discoloration
  • Visible hot spots
  • Warped exterior steel
  • Damaged fasteners
  • Air leakage around doors or flanges
  • Unusual heat near platforms, wiring or control components

An untreated hot spot can expand quickly. In severe cases, heat can damage the shell or create a path for hot gases to escape. Your personnel or electronics may be in danger from the hot gases, and your RTO may be at risk of significant downtime. Call us for guidance if you’re seeing any paint discoloration, hot spots, or air leaks.

Cold-Face Support Inspection and Repair

The cold-face support holds thousands of pounds of ceramic media while being exposed to heat, condensation, process compounds and pressure changes.

Common signs of damage include:

  • Corrosion
  • Warped or torn metal
  • Broken supports
  • Media leakage
  • Plugging at the bottom of the bed
  • Structural deterioration
  • Gaps between the media and insulation

Cold-face support failure can allow media to shift, collapse or enter lower duct sections. Because much of the structure isn’t visible during normal operation, suspected support damage requires an internal inspection.

Dampers, Ductwork and Air-Leak Repair

The RTO can’t operate as designed when damaged dampers, leaking ductwork or failed expansion joints disrupt airflow.

Maintenance may include inspection and repair of:

  • Hot side bypass dampers
  • Isolation dampers
  • Process exhaust ductwork
  • Expansion joints
  • Access doors and flanges
  • Duct supports
  • Insulation and cladding
  • Corroded or damaged transition sections

Air leakage can reduce process capture, dilute the VOC concentration entering the oxidizer, increase fan demand and make system balancing more difficult. Hot side leaks can also create immediate safety and equipment risks.

What Affects RTO Maintenance Cost?

There’s no standard RTO maintenance cost because the scope is huge. Maintenance services can range from remote troubleshooting or a small component replacement all the way to a complete media changeout or system rebuild.

Primary cost factors include:

  • RTO size and design
  • Number of chambers
  • Equipment age and overall condition
  • Type and quantity of ceramic media
  • Accessibility of internal components
  • Amount and type of process contamination
  • Required labor and crane or rigging support
  • Replacement part availability
  • Age and availability of control system components
  • Travel and site requirements
  • Whether the work is planned or performed during an emergency shutdown
  • Whether related ductwork, dampers or process equipment also require repair

The lowest-cost repair isn’t always the most economical long-term option. Replacing a failed component without correcting the condition that caused it can lead to repeat downtime.

Kono Kogs technicians evaluate the immediate problem together with the RTO system’s age, operating history and remaining service life. We explain the practical options and trade-offs so you can decide whether to repair, upgrade, rebuild or replace the equipment.

Repair, Upgrade or Rebuild?

Maintenance might reveal that a problem is larger than a single failed part. But that doesn’t automatically mean the entire RTO has to be replaced.

A repair may be appropriate when:

  • The problem is isolated
  • The underlying equipment remains structurally sound
  • Replacement parts are available
  • The system still meets current process requirements

An upgrade may be appropriate when:

  • Controls or drives are obsolete
  • Valve operation is unreliable
  • Process conditions have changed
  • Remote access or improved diagnostics are needed
  • A recurring design problem can be corrected

A rebuild may be appropriate when:

  • Multiple major components have deteriorated
  • Internal insulation and structural steel require extensive work
  • The ceramic media and support system need replacement
  • The shell and basic equipment configuration remain usable
  • Rebuilding offers a lower total cost than purchasing a new RTO

Our technicians work on equipment from all major OEMs and can assess the complete system rather than limiting our recommendation to one component or brand.

Emergency RTO Repair

An RTO shutdown can interrupt production and put your facility at risk of operating outside its permitted emissions-control requirements.

Kono Kogs provides 24/7 emergency service for problems such as:

  • RTO shutdowns
  • Valve failures
  • Burner faults
  • PLC and control failures
  • Fan or VFD problems
  • Severe hot spots
  • Insulation or shell damage
  • Damper failures
  • Media collapse or excessive pressure drop

For emergency RTO service, call Dan: 920-615-8804

Put our RTO experience to work

Kono Kogs provides professional diagnosis, repair and upgrade services for regenerative thermal oxidizers and other VOC abatement equipment.

Our technicians evaluate the root cause of the problem, explain all the available options and recommend the most cost-effective path based on system condition, operating requirements and expected equipment life. Tell us what your RTO is doing (or not doing) and we’ll help you figure out the next step.

Request RTO Service

For emergency RTO service, call Dan: 920-615-8804

RTO Maintenance FAQs

RTO maintenance raises plenty of practical questions. Here are answers to common questions, based on what we see in the field.

How often does an RTO need maintenance?

Maintenance frequency depends on operating hours, process contaminants, RTO design and equipment condition. Operators should monitor performance continuously and investigate changes promptly. Internal inspections and major service are typically coordinated with planned outages and manufacturer recommendations.

What is the most common RTO maintenance problem?

Ceramic media plugging is one of the most common problems, especially in applications with particulate, silicones, resins, oils or sticky VOCs. Valve wear, instrumentation problems and insulation hot spots are also frequent service issues.

How do I know whether the ceramic media needs cleaning or replacement?

Pressure drop, airflow, temperature profiles, fuel use and internal condition all help determine whether cleaning is practical. Media that’s crushed, chemically damaged, collapsed or permanently fouled generally requires replacement.

Can an RTO be maintained by a company other than the original manufacturer?

Yes. An experienced oxidizer service provider like Kono Kogs can inspect, troubleshoot, repair and upgrade equipment from multiple OEMs. This can be especially helpful for older systems, discontinued models or equipment with obsolete controls.

What causes increased RTO maintenance costs?

Emergency work, difficult access, obsolete parts, extensive media contamination and damage that affects several connected components can all increase cost. Planning work during a scheduled outage usually provides more options and reduces production disruption.

Can maintenance reduce RTO fuel consumption?

Yes, maintenance can reduce fuel consumption when higher fuel use is caused by plugged media, air leakage, improper burner adjustment, sensor problems, valve leakage or reduced heat recovery. The underlying cause should be diagnosed rather than assuming the burner is the only issue.

When should an RTO be rebuilt instead of repaired?

A rebuild may make sense when several major components require work but the shell and overall configuration remain suitable for the application. Kono Kogs can compare repair, rebuilding and replacement based on the expected cost, downtime and service life of each option.

Featured Case Study

RTO Insulation, Damper and Duct Repair

A Fortune 500 customer needed to replace a locked-up hot-side bypass damper and related ductwork along with repairing an insulated roof section on their large RTO.

Read the Case Study
RTO Insulation, Damper and Duct Repair
Before
After